==User Manual==
1. '''X-UPS1 V1.3 Jumper Cap & Button Switch Guidance:'''
[[File:X-ups1-IMG-5311-Jumper-Cap.jpg|750px|Jumper Cap & Button Switch Function]]
 
2. Guide based on the Raspberry Pi 5;
 
If you are using the X-UPS1 with the Raspberry Pi 5, you will need to do the following configuration on the Raspberry Pi 5:
 
From the command line or Terminal window start by running the following command :
sudo rpi-eeprom-config -e
Change the setting of '''POWER_OFF_ON_HALT''' from '''0''' to '''1''' ,
 
Add '''PSU_MAX_CURRENT=5000''' at the end of the file that reads like this:
 
[[File:X120x setting1.png]]
==Application==