==User Manual==
'''1. X-UPS1 V1.3 Jumper Cap & Button Switch Guidance:'''
[[File:X-ups1-IMG-5311-Jumper-Cap.jpg|750px|Jumper Cap & Button Switch Function]]
 
'''2. Guide based on the Raspberry Pi 5;'''
 
If you are using the X-UPS1 with the Raspberry Pi 5, you will need to do the following configuration on the Raspberry Pi 5:
 
From the command line or Terminal window start by running the following command :
sudo rpi-eeprom-config -e
Change the setting of '''POWER_OFF_ON_HALT''' from '''0''' to '''1''' ,
 
Add '''PSU_MAX_CURRENT=5000''' at the end of the file that reads like this:
 
[[File:X120x setting1.png]]
 
Then reboot your Raspberry Pi 5 to make the change take effect.
sudo reboot
==Application==
* Please watch Main Video and Tutorial Video regarding 18650 batteries at: https://www.staysafebattery.com/en/
* Battery Recommend for X-UPS1 board, please refer to: [[File:NCR18650B.pdf|X728 battery recommend]]
 
==FAQ==
<div class="toccolours mw-collapsible mw-collapsed">
<div style="font-weight:bold;line-height:1.0;">
Q: About X-UPS1 External PH2.0-4P Switch
</div>
<div class="mw-collapsible-content">
A: The X-UPS1 has a JST PH2.0-4P switch connector reserved to allow you to use an external reset switch to fulfill the function of the on-board switch in appropriate scenarios.
Care needs to be taken to use the correct wiring sequence for your momentary self-reset switch, please refer to the silkscreen description on the PCB board, you can refer to [[PSW19]] or purchase it from https://geekworm.com/products/power-control-switch-for-x820-or-x735
 
</div>
</div>
 
 