Open main menu

Changes

X-UPS1

1,574 bytes added, 17 April
[[File:X-UPS-1-IMG-5330.jpg|thumb|right|Sackable & universal UPS shiled, 12V & 5V dual output voltage for all SBC]]
[[File:X-ups1-acce-size.jpg|thumb|right|X-UPS V1.3 Accessories & Dimension]]
[[File:X-ups1-acce-size.jpg|thumb|right|X-UPS V1.3 dimension]]
[[File:X-ups1-IMG-5308.jpg|thumb|right|X-UPS1 V1.3]]
[[File:X-ups1-IMG-5310.jpg|thumb|right|X-UPS1 V1.3]]
|-
| '''Key Features''' ||
'''Power Input'''
* Integrated highefficiency stepdown DC/DC converter
* Wide 6V to 24V operating input range
* Up to 95% Efficiency
* Allows powering from a car, a solder pannel and other power sources
* Most common power input jack: 5.5x2.1mm
 
'''Power Output'''
* Provides dual 12Vdc & 5Vdc or single 5Vdc output
* <span style="color:red;">Each board provides max 12V/3A or 5V/3A power backup</span>
* <span style="color:red;">Can be stacked to increase output current and battery life</span>
* <span style="color:red;">Total output current could be 3A multiplied by the quantity of boards .</span>For example, one X-UPS1 can output 3A, two are 6A, three are 9A, and so on
* Reverse Current Protection
* Integrate Advanced Power MOSFET with Equivalent of 7mΩ RDS(ON) to reduce power loss
* 18650 4cell lithium Ion holders
* When stacked, multiple power adapters can be used to charge at the same time
 
'''Power Input'''
* Integrated highefficiency stepdown DC/DC converter
* Wide 6V to 24V operating input range
* Up to 95% Efficiency
* Up to 10A output current to keep 3A fast charging and powering your SBC at the same time
* Allows powering from a car, a solder pannel and other power sources
* Most common power input jack: 5.5x2.1mm
'''Power Control'''
* <span style="color:red;font-weight:bold">LBAT:</span> <span style="color:red">A high level will be triggered when the battery voltage is lower than or equal to 3V (You can't modify this threshold of 3V)</span>
* <span style="color:red;font-weight:bold">PLD:</span> <span style="color:red">(AC power loss detection), When the external power supply is disconnected, it will trigger a high level, and the indicator light will be on</span>
* <span class="tb_red">You can program it yourself to read the above PLD and LBAT pin GPIO signals to achieve your own more advanced functions such as '''low battery monitoring''' and '''power failure detection''', which can be referred to the '''plsd.py''' file of [[X708-script]]. We do not provide example programs</span>
|-
|'''Spec''' ||
==User Manual==
'''1. X-UPS1 V1.3 Jumper Cap & Button Switch Guidance:'''
[[File:X-ups1-IMG-5311-Jumper-Cap.jpg|750px|Jumper Cap & Button Switch Function]]
 
'''2. Guide based on the Raspberry Pi 5;'''
 
If you are using the X-UPS1 with the Raspberry Pi 5, you will need to do the following configuration on the Raspberry Pi 5:
 
From the command line or Terminal window start by running the following command :
sudo rpi-eeprom-config -e
Change the setting of '''POWER_OFF_ON_HALT''' from '''0''' to '''1''' ,
 
Add '''PSU_MAX_CURRENT=5000''' at the end of the file that reads like this:
 
[[File:X120x setting1.png]]
 
Then reboot your Raspberry Pi 5 to make the change take effect.
sudo reboot
==Application==
* Please watch Main Video and Tutorial Video regarding 18650 batteries at: https://www.staysafebattery.com/en/
* Battery Recommend for X-UPS1 board, please refer to: [[File:NCR18650B.pdf|X728 battery recommend]]
 
==FAQ==
<div class="toccolours mw-collapsible mw-collapsed">
<div style="font-weight:bold;line-height:1.0;">
Q: About X-UPS1 External PH2.0-4P Switch
</div>
<div class="mw-collapsible-content">
A: The X-UPS1 has a JST PH2.0-4P switch connector reserved to allow you to use an external reset switch to fulfill the function of the on-board switch in appropriate scenarios.
Care needs to be taken to use the correct wiring sequence for your momentary self-reset switch, please refer to the silkscreen description on the PCB board, you can refer to [[PSW19]] or purchase it from https://geekworm.com/products/power-control-switch-for-x820-or-x735
 
</div>