==Overview==
The X-UPS1 is an universal stackable uninterruptible power supply (UPS) stackable module shield for most Single-Board Computers (SBC) that uses 12Vdc or 5Vdc. The UPS ensures that in event of power interruption, a battery or any other power source will intervene without any effect on your board.
Our convenient stackable design allows you to connect several UPS modules on your boards to provide long-lasting & higher output power for even the most demanding SBC set ups that have constant power connections 24 hours a day, seven days a week.
==Features==
{| class="wikitable"
|-
| '''For use with''' || Most Single-Board Computers (SBC) that uses 12Vdc or 5Vdc, * SBC Example: Orange Pi 5 / Jetson Nano / Raspberry Pi / Tinker Board / Arduino etc.
|-
| '''Key Features''' ||
'''UPS Power Input'''* Integrated highefficiency stepdown DC/DC converter* Wide 6V to 24V operating input range* Up to 95% Efficiency* Allows powering from a car, a solder pannel and other power sources* Most common power input jack: 5.5x2.1mm '''Power Output'''
* Provides dual 12Vdc & 5Vdc or single 5Vdc output
* <span style="color:red;">Each board provides max 12V/3A or 5V/3A power backup</span>* <span style="color:red;">Can be stacked to increase output current and battery life</span>* <span style="color:red;">Total output current could be 3A multiplied by the No. quantity of boards .</span>For example, one X-UPS1 can output 3A, two are 6A, three are 9A, and so on
* Reverse Current Protection
* Integrate Advanced Power MOSFET with Equivalent of 7mΩ RDS(ON) to reduce power loss
* Onboard 4 green LEDs indicate battery charging and discharging levels of 25%, 50% , 75% and 100%
* 18650 4cell lithium Ion holders
 '''Power Input'''* Integrated highefficiency stepdown DCDC converter* Wide 6V When stacked, multiple power adapters can be used to 24V operating input range* Up to 95% Efficiency* Up to 10A output current to keep 3A fast charging and powering your SBC charge at the same time* Allows powering from a car, a solder pannel and other power sources* Most common power input jack: 5.5x2.1mm
'''Power Control'''
'''Misc'''
* Power output connectors : VH3.96 x2 (12V) / XH2.54 x2 (5V) / USB TypeA x2 (5V)
* PH2.04P 0-4P for external power switch* PH2.04P 0-4P for <span style="color:red;font-weight:bold">LBAT</span> (low battery output ) and <span style="color:red;font-weight:bold">PLD</span> (AC power loss deteciton) detection)* <span style="color:red;font-weight:bold">LBAT:</span> <span style="color:red">A high level will be triggered when the battery voltage is lower than or equal to 3V (You can't modify this threshold of 3V)</span>* <span style="color:red;font-weight:bold">PLD:</span> <span style="color:red">(AC power loss detection), When the external power supply is disconnected, it will trigger a high level, and the indicator light will be on</span>* <span class="tb_red">You can program it yourself to read the above PLD and LBAT pin GPIO signals to achieve your own more advanced functions such as '''low battery monitoring''' and '''power failure detection''', which can be referred to the '''plsd.py''' file of [[X708-script]]. We do not provide example programs</span>
|-
|'''Spec''' ||
|'''Note''' ||
<span style="color:red;font-weight:bold"> Notes for stackable application: </span>
# All power input are connected together via the 18-pin female header, input output current is subject to the No. quantity of boards.# You can use same one board to turn on/off all stackable boards. (be noted that which board you press the button to turn on, also must the same board to turn off.)# If the Only one AL_ON jumper caps be shorted to enable Always Power On when stacked multiple x-ups1 shields.# MUST ALL 12 OFF jumper for auto power on is inserted on one board, then this funciton will caps be enabled for all stackable boardsshorted to disable 12V output when stacked multiple x-ups1 shields.
|}
==Packing List==
* 1 x X-UPS1 Expansion Board
* 1 x VH3.96 to DC5525 Cable (50cm length, to 12V DC5525output)* 1 x XH2.54 to DC5521 Cable (50cm length, to 5V DC5521output)* 1 x Power 4Pin PH2.0 to dupont cable (30cm length, this is a signal & 5V Output Cable)* 1 x GPIO daughter boardHeader
* 2 x Jumper link Pitch 2.54mm
* 4x Spacer F/F M2.5x10mm
==User Manual==
'''1. X-UPS1 V1.3 Jumper Cap & Button Switch Guidance:''' [[File:X-ups1-IMG-5311-Jumper-Cap.jpg|750px|Jumper Cap & Button Switch Function]] '''2. Guide based on the Raspberry Pi 5;''' If you are using the X-UPS1 with the Raspberry Pi 5, you will need to do the following configuration on the Raspberry Pi 5: From the command line or Terminal window start by running the following command : sudo rpi-eeprom-config -e Change the setting of '''POWER_OFF_ON_HALT''' from '''0''' to '''1''' , Add '''PSU_MAX_CURRENT=5000''' at the end of the file that reads like this: [[File:X120x setting1.png]] Then reboot your Raspberry Pi 5 to make the change take effect. sudo reboot ==Application==Compatible with Most Single Board Computers (SBC) that uses 12Vdc or 5Vdc, SBC Example: Orange Pi 5 / Jetson Nano / Raspberry Pi / Tinker Board / Arduino etc.<gallery>X-UPS1-IMG-5409.jpg|X-UPS1 for Raspberry PiX-UPS1-IMG-5410.jpg|X-UPS1 for Orange PiX-UPS1-IMG-5411.jpg|X-UPS1 for Jetson Nano</gallery> ==PCB dimentionDimension==
X-UPS1 Dimensions source file (DXF): [[File:X-UPS1-PCB.dxf]] - You can view it with Autodesk Viewer online
 
==SAFETY INSTRUCTIONS AND WARNINGS==
* <span style="color:red;">You must read these safety instructions and warnings before charging your batteries.
* <span style="color:red;">Lithium Polymer and Li-ion batteries are volatile. Failure to read and follow the below instructions may result in fire, personal injury and damage to property if charged or used improperly.
* <span style="color:red;">Never make wrong polarity connection when charging and discharging battery packs. Always double check polarity of battery's connector to make sure "+" to "+" and "-" to "-".
* <span style="color:red;">Do not mix and use old batteries and new batteries, or batteries with different brand names.
* <span style="color:red;">Lithium batteries has it's cycle life, please replace old battery with new one when it reaches it's service life or when it is two year old, whichever comes first.
* <span style="color:red;">When charging Battery Pack, please put battery in a fire proof container. Please don't leave the X-UPS1 on the wood material or carpet and unattended.
* <span style="color:red;">Must keep the X-UPS1 away from children.
* Please watch Main Video and Tutorial Video regarding 18650 batteries at: https://www.staysafebattery.com/en/
* Battery Recommend for X-UPS1 board, please refer to: [[File:NCR18650B.pdf|X728 battery recommend]]
 
==FAQ==
<div class="toccolours mw-collapsible mw-collapsed">
<div style="font-weight:bold;line-height:1.0;">
Q: About X-UPS1 External PH2.0-4P Switch
</div>
<div class="mw-collapsible-content">
A: The X-UPS1 has a JST PH2.0-4P switch connector reserved to allow you to use an external reset switch to fulfill the function of the on-board switch in appropriate scenarios.
Care needs to be taken to use the correct wiring sequence for your momentary self-reset switch, please refer to the silkscreen description on the PCB board, you can refer to [[PSW19]] or purchase it from https://geekworm.com/products/power-control-switch-for-x820-or-x735
 