==Features==
{| class="wikitable"
|-
| '''For use with''' || most Single-Board Computers (SBC) that uses 12Vdc or 5Vdc
|-
| '''Key Features''' ||
'''UPS Output'''
* Provides dual 12Vdc & 5Vdc or single 5Vdc output
* Each board provides max 3A power backup
* Can be stacked to increase output current and battery life
* Total output current could be 3A multiplied by the No. of boards
* Reverse Current Protection
* Integrate Advanced Power MOSFET with Equivalent of 7mΩ RDS(ON) to reduce power loss
 
'''Battery Charging'''
* Supports 3000mA fast battery charging
* Battery over current protection and over voltage protection
* Protection of battery cell Reverse Connection
* Lowbattery detection (LED and 3.3V level output)
* Onboard 4 green LEDs indicate battery charging and discharging levels of 25%, 50% , 75% and 100%
* 18650 4cell lithium Ion holders
 
'''Power Input'''
* Integrated highefficiency stepdown DCDC converter
* Wide 6V to 24V operating input range
* Up to 95% Efficiency
* Up to 10A output current to keep 3A fast charging and powering your SBC at the same time
* Allows powering from a car, a solder pannel and other power sources
* Most common power input jack: 5.5x2.1mm
 
'''Power Control'''
* Onboard push button to control power on /off (PressON, Hold the button pressed at least 3s OFF )
* Onboard LEDs shows the status of power output
* AC power loss or power adapter failure detection (LED and 3.3V level output)
* Jumper setting to enable Auto power on when power applied or restored
* Jumper setting to disable 12V output
* Ultralow standby power consumption to maximize battery life
* Advanced system powerpath management avoids batteries frequent charging and discharging
 
'''Misc'''
* Power output connectors : VH3.96 x2 (12V) / XH2.54 x2 (5V) / USB TypeA x2 (5V)
* PH2.04P for external power switch
* PH2.04P for low battery output and AC power loss deteciton
|-
|'''Spec''' ||
* Power input (Single board) : 624Vdc ±5%, ≥3A
* UPS output voltage : 12Vdc ±5%, 5.1Vdc ±5%
* UPS output current (Single boards) : Max 3A
* UPS output current (Stackable boards) : 3A x No. of the boards
* UPS charging current (Single board) : 2.3~3.2A
* Terminal Battery Voltage : 4.24V
* Battery Recharge Threshold : 4.1V
* Battery low detection: ≤3V
|-
|'''Note''' ||
<span style="color:red;font-weight:bold"> Notes for stackable application: </span>
# All power input are connected together via the 18-pin female header, input current is subject to the No. of boards.
# You can use one board to turn on/off all stackable boards. (be noted that which board you press the button to turn on, also must the same board to turn off.)
# If the jumper for auto power on is inserted on one board, then this funciton will be enabled for all stackable boards.
|}
==Packing List==