A: This is the intended design logic of the X-UPS1 to ensure system stability and battery safety and is not a defect. | A: This is the intended design logic of the X-UPS1 to ensure system stability and battery safety and is not a defect. | ||
* '''Sequential Discharge:''' Each board has an over-discharge protection circuit. The primary board will power the system until it reaches a low-voltage threshold, at which point the next board automatically takes over. | * '''Sequential Discharge:''' Each board has an '''over-discharge protection circuit'''. The primary board will power the system until it reaches a low-voltage threshold, at which point the next board automatically takes over. | ||
* '''Voltage Priority:''' Due to minor hardware tolerances, the board with the highest voltage naturally bears the load first, preventing power conflicts between packs. | * '''Voltage Priority:''' Due to minor hardware tolerances, the board with the highest voltage naturally bears the load first, preventing power conflicts between packs. | ||
* '''Power Priority:''' When external power is connected, the UPS prioritizes external power for the system, and all batteries switch to charging mode only. | * '''Power Priority:''' When external power is connected, the UPS '''prioritizes external power''' for the system, and all batteries switch to charging mode only. | ||