Q9: What battery is recommended for this ups UPS shield?
</div>
<div class="mw-collapsible-content">
If using a lithium battery, the required voltage is 3.7V;
if If using a battery packor battery holder, please make sure it is a parallel battery pack. '''Please use a high-quality battery holder with thick and durable connection cables. Using a low-quality battery holder with thin or poorly connected wires may cause the X1203 to malfunction or fail to operate as expected.''' 
There are 2 XH2.54-2P battery connectors on board, it is recommended to use the same type of battery.
[https://www.analog.com/media/en/technical-documentation/data-sheets/MAX17040-MAX17041.pdf MAX17040G+]
</div>
</div>
 
<div class="toccolours mw-collapsible mw-collapsed">
<div style="font-weight:bold;line-height:1.0;">
Q14. Why does the RPI 5 lose power within a few seconds after pressing the power button on the X120x UPS?
</div>
<div class="mw-collapsible-content">
A:
 
'''Please note: If the UPS does not detect the RPi5, it will automatically shut down within 3 seconds. So you need to install the RPi 5 on the UPS and make sure that the RPi5 has good contact with the UPS's pogo pins.'''
 
</div>
</div>
 
<div class="toccolours mw-collapsible mw-collapsed">
<div style="font-weight:bold;line-height:1.0;">
Q15. Which product should I choose if I can’t connect to a Raspberry Pi via pogo pins?
</div>
<div class="mw-collapsible-content">
A:
 
For the X12-UPS series, we recommend the '''[[X1206]]''' – models from X1200 to X1205 do not support this usage. The X120- UPS series auto-powers off when no Raspberry Pi 5 is detected, while the X1206 can be set to "Always Power On" mode and keeps working even if the Raspberry Pi is shut down. Please refer to <span style="color:red">'''Interface ⑩_ALON'''</span> in the picture.
 
[[File:X1206-IMG-7240-Interface-New.jpg|800px]]
You can also consider the '''[[X-UPS1]]'''. It features a GPIO Pin-Connected standalone design with high flexibility for installation and adaptation (refer to the picture).
[[File:X-UPS1-IMG-5409.jpg|800px]]
</div>