==Safety Instructions & Warnings==
 
==Safety Instructions & Warnings==
* <span class="tb_red">You must read these safety instructions and warnings before charging your batteries.  
+
'''⚠''' <span class="tb_red">The default charging current is set to 1.5A and charge cut-off voltage is 4.23V. before installing your battery in the UPS board, Please carefully confirm the maximum charging current and voltage, exceeding the upper limit of the charging specification that the battery can withstand will not only cause adverse reactions, but may also cause irreversible damage.
* <span class="tb_red">Lithium Polymer and Li-ion batteries are volatile. Failure to read and follow the below instructions may result in fire, personal injury and damage to property if charged or used improperly.
+
 
* <span class="tb_red">Never make wrong polarity connection when charging and discharging battery packs. Always double check polarity of battery's connector to make sure "+" to "+" and "-" to "-".
+
'''⚠''' <span class="tb_red">It is essential to read and understand these safety instructions and warnings before charging your batteries.
* <span class="tb_red">Do not mix and use old batteries and new batteries, or batteries with different brand names.
+
 
* <span class="tb_red">Lithium batteries has it's cycle life, please replace old battery with new one when it reaches it's service life or when it is two year old, whichever comes first.
+
'''⚠''' <span class="tb_red">Lithium Polymer and Li-ion batteries are volatile. Failure to read and follow the instructions below may result in fire, personal   injury, and damage to property if charged or used improperly.
* <span class="tb_red">When charging Battery Pack, please put battery in a fire proof container. Please don't leave the UPS shield on the wood material or carpet and unattended.
+
 
 +
'''⚠''' <span class="tb_red">Never make a wrong polarity connection when charging or discharging battery packs. Always double-check the polarity of the  battery's connector to ensure that "+" is connected to "+" and "-" is connected to "-".
 +
 
 +
'''⚠''' <span class="tb_red">Do not mix and use old batteries with new batteries, or batteries with different brand names.
 +
 
 +
'''⚠''' <span class="tb_red">Lithium batteries have a limited cycle life. Please replace old batteries with new ones when they reach their service life or when   they are two years old, whichever comes first.
 +
 
 +
'''⚠''' <span class="tb_red">When charging the Battery Pack, please place the battery in a fireproof container. Do not leave the UPS shield on wood material   or carpet unattended.
 +
 
 +
'''⚠''' <span class="tb_red">Keep the UPS shield away from children to ensure their safety.
  
 
==Overview==
 
==Overview==

Revision as of 15:20, 17 September 2025

Safety Instructions & Warnings

The default charging current is set to 1.5A and charge cut-off voltage is 4.23V. before installing your battery in the UPS board, Please carefully confirm the maximum charging current and voltage, exceeding the upper limit of the charging specification that the battery can withstand will not only cause adverse reactions, but may also cause irreversible damage.

It is essential to read and understand these safety instructions and warnings before charging your batteries.

Lithium Polymer and Li-ion batteries are volatile. Failure to read and follow the instructions below may result in fire, personal injury, and damage to property if charged or used improperly.

Never make a wrong polarity connection when charging or discharging battery packs. Always double-check the polarity of the battery's connector to ensure that "+" is connected to "+" and "-" is connected to "-".

Do not mix and use old batteries with new batteries, or batteries with different brand names.

Lithium batteries have a limited cycle life. Please replace old batteries with new ones when they reach their service life or when they are two years old, whichever comes first.

When charging the Battery Pack, please place the battery in a fireproof container. Do not leave the UPS shield on wood material or carpet unattended.

Keep the UPS shield away from children to ensure their safety.

Overview

The X1207 is a PoE-powered UPS HAT designed for Raspberry Pi 5, delivering reliable 5.1V/5A backup power to maintain uninterrupted operation. It supports high-demand setups and complies with IEEE 802.3af/at PoE standards, drawing up to 25W from a compatible POE switch while providing both power and network connectivity over a single cable.

With intelligent power management, it monitors Pi status, cuts power after shutdown to conserve battery, and features ultra-low standby consumption. The board ensures seamless power switching during outages and supports auto power-on and AC loss detection.

Features

Technical specification

Power input
  • 35-57VDC powering over Ethernet
  • 5Vdc 5A via USB-C
UPS output 5.1V ±5% Max 5A
Battery charging current 1.5A
Terminal Battery Voltage 4.23V
Battery Recharge Threshold 4.1V
Ports & Connectors
  • 4-pin POE female header x1
  • USB-C power in connector x1
  • 1-cell 21700 battery connector x1
  • 40-pin extended GPIO header x1
PCB Size 86.5mm x 84.5mm

Packing List

  • X1207 V1.2 UPS board x 1
  • Spacer M2.5 F/F 13.5mm x 4
  • Screw M2.5x5mm x 8
  • Pogo pin x 1 (For connecting to the Pi 5 PSW through hole)

User Manual

FAQ