Related changes
← X1202
Jump to navigation
Jump to search
Enter a page name to see changes on pages linked to or from that page. (To see members of a category, enter Category:Name of category). Changes to pages on your Watchlist are in bold.
List of abbreviations:
- N
- This edit created a new page (also see list of new pages)
- m
- This is a minor edit
- b
- This edit was performed by a bot
- (±123)
- The page size changed by this number of bytes
15 June 2024
14 June 2024
|
14:09 | (Comments log)[Lisa; 136.52.124.58] | |||
|
14:09 Lisa talk contribs posted a new comment on X1203 (Hi,The charging voltage and current cannot be modified.) | ||||
|
11:43 136.52.124.58 talk posted a new comment on X1203 (Is it possible to modify the maximum charge voltage? For safety and longevity of the cells I would like them charged no higher than 3.75v - Is it possible for the user to make this change? Is it also possible to modify the minimum voltage before automatic shutdown is triggered? Is it possible to modify the maximum charge current? Control over all of these settings would not only allow for safer operation and longer battery lifespan but would also allow for the use of LiFePO4 cells which ar...) |
13 June 2024
12 June 2024
|
15:59 | (Comments log)[174.174.80.39; Harry; Lisa (2×)] | |||
|
15:59 Lisa talk contribs deleted comment #4853 on X1200 | ||||
|
15:59 Lisa talk contribs posted a new comment on X1200 (Yes, you can write a ''timer'' script, set a time value and check it.) | ||||
|
15:51 Harry talk contribs posted a new comment on X1200 (Yes. You can do this via script, just implement a timer in the script.) | ||||
|
01:28 174.174.80.39 talk posted a new comment on X1200 (OK so I got pretty close by modifying the included pld.py script. I can get it to shutdown when on battery with a delay. However, it will execute the second the pi is on battery. I would rather it be on battery for say 10 seconds so random power drops don't shut it down. Any idea on how to implement this? #!/usr/bin/env python3 #This python script is only suitable for UPS Shield X1200, X1201 and X1202 import gpiod import time from subprocess import call PLD_PIN = 6 chip = gpiod.Chip('gpioc...) |
10 June 2024
09:36 | Comments log 174.174.80.39 talk posted a new comment on X1200 (Is it possible to change the auto shutdown behavior to turn the raspberry pi off after a certain amount of time on battery rather than when the battery is low?) |
7 June 2024
|
11:10 | X1203 2 changes history+242 [Lisa; Abby] | |||
|
11:10 (cur | prev) +66 Abby talk contribs | ||||
|
10:31 (cur | prev) +176 Lisa talk contribs →Features |
|
09:57 | (Comments log)[Lisa (5×)] | |||
|
09:57 Lisa talk contribs posted a new comment on X1203 (Hi,X1203 compatible with X708-A1 battery holder. But it is not possible to install the X708-A1 under the X1203 because there are no mounting holes on the x1203 board.) | ||||
|
09:55 Lisa talk contribs deleted comment #4836 on X1203 | ||||
|
09:42 Lisa talk contribs posted a new comment on X1203 (Hi,yes, you can use X1203 with X708-A1 Battery Holder.) | ||||
|
09:41 Lisa talk contribs deleted comment #4835 on X1203 | ||||
|
09:41 Lisa talk contribs posted a new comment on X1203 (Hi,yes you can use X1203 with X1078-A1) |
6 June 2024
|
15:39 | Template:X120x-FAQ 3 changes history+2 [Cindy (3×)] | |||
|
15:39 (cur | prev) +1 Cindy talk contribs | ||||
|
15:38 (cur | prev) -573 Cindy talk contribs | ||||
|
15:37 (cur | prev) +574 Cindy talk contribs |
|
15:36 | X1201 2 changes history-30 [Abby (2×)] | |||
|
15:36 (cur | prev) 0 Abby talk contribs | ||||
|
15:36 (cur | prev) -30 Abby talk contribs |
|
15:35 | X1200 3 changes history-28 [Abby (3×)] | |||
|
15:35 (cur | prev) +2 Abby talk contribs →Packing List | ||||
|
15:34 (cur | prev) 0 Abby talk contribs | ||||
|
15:34 (cur | prev) -30 Abby talk contribs |
05:29 | Comments log 216.24.212.41 talk posted a new comment on X1203 (Is the 1203 board compatible with the X708-A1 8-cell 18650 Battery Holder?) |
5 June 2024
|
14:36 | (Comments log)[Lisa; 216.24.212.226] | |||
|
14:36 Lisa talk contribs posted a new comment on X1203 (Hi,Battery Recharge Threshold: 4.1V) | ||||
|
04:59 216.24.212.226 talk posted a new comment on X1203 (The spec sheet for the recommended Panasonic batteries NCR18650B says max charging voltage is 4.20v, however the specs here state that the Terminal Battery Voltage = 4.23V. Shouldn't the 1203 cut off charging at 4.20V?) |