Power Jack and Connectors
Power input | 5Vdc +/- 5% ,≥4A |
DC Power Plug Size | 5.5*2.5mm |
Power input connector | XH2.54mm 2pin |
UPS power output | 5.1Vdc 8A |
Power output connector | XH2.54mm 2pin |
- T208 powers the Jetson Nano via the 40-pin header (Pin 2 & 4)
- Don't power the Jetson Nano via the Micro USB socket & DC jack
- T208 can be powered via the onboard DC jack or XH2.54 power input connector.
4-Pin Function Header
Jumper Name | Usage |
---|---|
PLD
(Power loss detection)" |
Short - AC Power loss or power adapter failure detection enabled
(Active if power adapter disconnected) Open - Power loss detection disabled |
AON
(Auto power-on) |
Short - Auto power-on when power applied
(Will delay 3 seconds before powering on) Open - Auto power-on disabled |
Connector for External Power Switch
Pin No. | Pin Description |
---|---|
1 | Power on/off control connecting to switch |
2 | Ground |
3 | Ground |
4 | LED+ for power on /off |
- Please use momentary switch only and don't use latching switch
- Connector - Pitch 2.0mm 4pos
Power button & control
Press and Release | Jetson Nano and T208 turn on |
Auto power off | System shutdown using the GUI |
Press and hold for at least 3 seconds | Force shutdown |
Function LEDs
LED Name | Usage |
---|---|
AC FAIL | LED red on indicates AC power loss or PSU failure or PSU disconnected |
PWR | LED blue indicates
Stays on - Power on Stays off - 5V power output off |
Pins and GPIO used
Pin No. | Usage |
---|---|
2, 4 | +5V power supply |
3, 5 | I2C for RTC and battery fuel-gauge systems |
6, 9 | Ground |
7 | GPIO6 for AC power loss detection (Jumper for PLD inserted, High=power loss,Low=Power supply normal) |
10 | NC not connected |
Fuel gauge - LED Indicator
Operation of Discharging:
Capacity C (%) | D1 | D2 | D3 | D4 |
---|---|---|---|---|
C ≥75% | ON | ON | ON | ON |
50%≤C<75% | ON | ON | ON | OFF |
25%≤C<50% | ON | ON | OFF | OFF |
3%≤C<25% | ON | OFF | OFF | OFF |
0%<C<3% | Flashing | OFF | OFF | OFF |
Operation of charging:
Capacity C (%) | D1 | D2 | D3 | D4 |
---|---|---|---|---|
Fully charged | ON | ON | ON | ON |
75%≤C | ON | ON | ON | Flashing |
50%≤C<75% | ON | ON | Flashing | OFF |
25%≤C<50% | ON | Flashing | OFF | OFF |
C<25% | Flashing | OFF | OFF | OFF |
Enable comment auto-refresher
Anonymous user #9
Permalink |
Anonymous user #8
Permalink |
Lisa
Anonymous user #8
Anonymous user #7
Permalink |
Harry
Anonymous user #6
Permalink |
Lisa
Anonymous user #5
Permalink |
Lisa
Anonymous user #4
Permalink |
Lisa
Anonymous user #2
Lisa
Anonymous user #3
Permalink |
Lisa
Anonymous user #2
Permalink |
Lisa
Anonymous user #1
Permalink |