==Safety Instructions & Warnings==
==Safety Instructions & Warnings==
① Short-circuiting the positive and negative terminals of the capacitors is strictly prohibited. Damage caused by a short circuit is not covered under warranty.
① Short-circuiting the positive and negative terminals of the capacitors is strictly prohibited. Damage caused by a short circuit is not covered under warranty.
Line 56: Line 64:
| '''Charging time''' || Approximately 15 minutes to fully charge (under 30W PD power supply conditions)
| '''Charging time''' || Approximately 15 minutes to fully charge (under 30W PD power supply conditions)
|-
|-
| ''Current and Voltage Detection''' ||  
| '''Current and Voltage Detection''' ||  
Identifies charging and discharging status;  
* Identifies charging and discharging status;  
 
* voltage and current of the supercapacitor can be read via I2C interface, and the direction of the current indicates whether it is charging or discharging;
voltage and current of the supercapacitor can be read via I2C interface, and the direction of the current indicates whether it is charging or discharging;
* I2C interface allows reading capacitor voltage and charging/discharging current.
 
I2C interface allows reading capacitor voltage and charging/discharging current.
|-
|-
| '''Power-down detection'''||  
| '''Power-down detection'''||  
One power-down detection pin;
*One power-down detection pin;
 
* a logic level of 3.3V indicates the presence of external power input, and a logic level of 0V indicates that the external power is off. For Raspberry Pi, external power loss can be detected via GPIO26 (40-pin);  
a logic level of 3.3V indicates the presence of external power input, and a logic level of 0V indicates that the external power is off. For Raspberry Pi, external power loss can be detected via GPIO26 (40-pin);  
* for other development boards, it can be connected to a GPIO pin.
 
for other development boards, it can be connected to a GPIO pin.


|-
|-
Line 89: Line 93:
* Supercapacitor UPS 5V 5A PD power module x 1
* Supercapacitor UPS 5V 5A PD power module x 1
* USB C-C adapter board x 4
* USB C-C adapter board x 4
[[File:UPS-Scap-5V5A-05.jpg  |600px]]


==Battery life==
==Battery life==
Line 96: Line 102:


100F version: Discharge begins at 5.2V:
100F version: Discharge begins at 5.2V:
[[File:UPS-Scap-5V5A-F8.jpg  |700px]]


==Related Explanation==
==Related Explanation==
Line 111: Line 119:
Several Timing Analysis Methods for Restoring Power Supply After a Supercapacitor Power Failure:
Several Timing Analysis Methods for Restoring Power Supply After a Supercapacitor Power Failure:


[[File:UPS-Scap-5V5A-F9.jpg | 700px]]


The supercapacitor UPS board has a microcontroller for power management. When external power is restored, it sends a power-on signal to the Raspberry Pi 5 via a pin. If the system is currently powered off, it will power on.
The supercapacitor UPS board has a microcontroller for power management. When external power is restored, it sends a power-on signal to the Raspberry Pi 5 via a pin. If the system is currently powered off, it will power on.
Line 120: Line 129:
The application needs to clear this dialog box promptly to prevent a forced shutdown triggered after two consecutive power outages and recoveries. The demo code provided by our company already includes the code to clear this dialog box.
The application needs to clear this dialog box promptly to prevent a forced shutdown triggered after two consecutive power outages and recoveries. The demo code provided by our company already includes the code to clear this dialog box.


Note: After executing the shutdown command, the screen will briefly display "plymouth-poweroff.service" for approximately 1-2 seconds. If power is restored during this time, the system will fail to boot and will remain in a shutdown state until the next power outage and restoration. The probability of entering this dead zone is extremely low; it is not a concern for local use. However, for remote unattended use, please carefully evaluate the situation.
'''Note: After executing the shutdown command, the screen will briefly display "plymouth-poweroff.service" for approximately 1-2 seconds. If power is restored during this time, the system will fail to boot and will remain in a shutdown state until the next power outage and restoration. The probability of entering this dead zone is extremely low; it is not a concern for local use. However, for remote unattended use, please carefully evaluate the situation.'''


==Real-time monitoring of voltage and current==
==Real-time monitoring of voltage and current==
Line 150: Line 159:
Open the Raspberry Pi terminal and download software to view real-time power parameters:
Open the Raspberry Pi terminal and download software to view real-time power parameters:


wget -O INA219.py http://www.mcuzone.com/wiki/3006_UPS_Scap_PD/INA219.py.zip
<nowiki>
<code bash>
wget -O INA219.py http://www.mcuzone.com/wiki/3006\_UPS\_Scap\_PD/INA219.py.zip
</code>
</nowiki>


Then run the software to see the real-time power parameters:
Then run the software to see the real-time power parameters:
Line 158: Line 171:
During charging:
During charging:


[[File:UPS-Scap-5V5A-R3.jpg | 500px]]
[[File:UPS-Scap-5V5A-R2-New.jpg | 500px]]


During discharge:
During discharge:


[[File:UPS-Scap-5V5A-R2.jpg | 500px]]
[[File:UPS-Scap-5V5A-R3-New.jpg | 500px]]


'''Note: The "current running time" here refers to the running time of the INA219.py program, not the actual charging time.'''
'''Note: The "current running time" here refers to the running time of the INA219.py program, not the actual charging time.'''
Line 196: Line 209:
Then download the software to view real-time power supply parameters:
Then download the software to view real-time power supply parameters:


<nowiki>
<code bash>
  wget -O INA219.py http://www.mcuzone.com/wiki/3006_UPS_Scap_PD/INA219.py.zip
  wget -O INA219.py http://www.mcuzone.com/wiki/3006_UPS_Scap_PD/INA219.py.zip
</code>
</nowiki>


Run the software to see the real-time power supply parameters:
Run the software to see the real-time power supply parameters:
Line 204: Line 221:
During charging:
During charging:


[[File:UPS-Scap-5V5A-U2.jpg | 500px]]
[[File:UPS-Scap-5V5A-U2-New.jpg | 500px]]


During discharge:
During discharge:
Line 215: Line 232:
This is how a supercapacitor UPS starts discharging when fully charged (capacitor voltage around 5.2V), then restarts charging when the capacitor voltage drops below 3V, until it is fully charged (capacitor voltage around 5.2V).
This is how a supercapacitor UPS starts discharging when fully charged (capacitor voltage around 5.2V), then restarts charging when the capacitor voltage drops below 3V, until it is fully charged (capacitor voltage around 5.2V).


==Power failure detection demonstration==
==User Manual==
 
Power failure detection demonstration:[http://wiki.mcuzone.com:81/index.php?title=3006_RPi5-UPS_Scap-PD_5V5A#%E5%85%AD%E3%80%81%E6%8E%89%E7%94%B5%E6%A3%80%E6%B5%8B%E6%BC%94%E7%A4%BA Power failure detection demonstration]
 
Real-time monitoring of voltage and current:[http://wiki.mcuzone.com:81/index.php?title=3006_RPi5-UPS_Scap-PD_5V5A#%E4%BA%94%E3%80%81%E7%94%B5%E5%8E%8B%E7%94%B5%E6%B5%81%E5%AE%9E%E6%97%B6%E7%9B%91%E6%B5%8B Real-time monitoring of voltage and current]


==FAQ==
==FAQ==