</div>
<div class="mw-collapsible-content">
A:Regarding the low voltage warning issue(Please refer to Q1 to check whether the connection is installed correctly):
* Please carefully check whether your hardware installation is secure and if the pogo pins are making proper contact. We have had cases where customers found that loose brass standoffs caused poor contact with the pogo pins, leading to the low voltage warning.
* It may be caused by an OS update. Please confirm whether you have recently updated the OS or if your OS system updates automatically.
<pre>
pi@geekworm:~ $ vcgencmd pmic_read_adc
3V7_WL_SW_A current(0)=0.00000000A00097593A 3V3_SYS_A current(1)=0.13663020A13955800A 1V8_SYS_A current(2)=0.25471770A25374180A DDR_VDD2_A current(3)=0.01951860A01854267A DDR_VDDQ_A current(4)=0.00000000A00049020A 1V1_SYS_A current(5)=0.25374180A25276590A 0V8_SW_A current(6)=0.34840700A34547920A VDD_CORE_A current(7)=0.98229990A87514000A 3V3_DAC_A current(17)=0.00000000A00024420A
3V3_ADC_A current(18)=0.00024420A
0V8_AON_A current(16)=0.00323565A00341880A HDMI_A current(22)=0.02039070A02063490A 3V7_WL_SW_V volt(8)=3.70348800V70534400V 3V3_SYS_V volt(9)=3.31003300V31467300V
1V8_SYS_V volt(10)=1.80024200V
DDR_VDD2_V volt(11)=1.10439400V11355200V DDR_VDDQ_V volt(12)=0.59816790V60109830V 1V1_SYS_V volt(13)=1.10329600V10622600V 0V8_SW_V volt(14)=0.80476110V80109810V VDD_CORE_V volt(15)=0.72043880V72017020V 3V3_DAC_V volt(20)=3.31043600V31318300V 3V3_ADC_V volt(21)=3.31776200V31684600V 0V8_AON_V volt(19)=0.79912020V80029220V HDMI_V volt(23)=5.11880000V19920000V EXT5V_V volt(24)=5.13756000V20322000V
BATT_V volt(25)=0.00000000V
</pre>
Please check the voltage value of <mark>EXT5V_V</mark> line
</div>
</div>
<div class="toccolours mw-collapsible mw-collapsed">
<div style="font-weight:bold;line-height:1.0;">
QQ4: How to disable '''auto power on''' feature on [[X1200]]?
</div>
<div class="mw-collapsible-content">
<div class="toccolours mw-collapsible mw-collapsed">
<div style="font-weight:bold;line-height:1.0;">
QQ7: How to disable '''auto power on''' feature on [[X1203]]?
</div>
<div class="mw-collapsible-content">
<div class="toccolours mw-collapsible mw-collapsed">
<div style="font-weight:bold;line-height:1.0;">
QQ8: Why is the RPi5 LED still on and red after the UPS is turned off?
</div>
<div class="mw-collapsible-content">
<div class="toccolours mw-collapsible mw-collapsed">
<div style="font-weight:bold;line-height:1.0;">
QQ9: What battery is recommended for this ups UPS shield?
</div>
<div class="mw-collapsible-content">
If using a lithium battery, the required voltage is 3.7V;
if If using a battery packor battery holder, please make sure it is a parallel battery pack. '''Please use a high-quality battery holder with thick and durable connection cables. Using a low-quality battery holder with thin or poorly connected wires may cause the X1203 to malfunction or fail to operate as expected.'''
There are 2 XH2.54-2P battery connectors on board, it is recommended to use the same type of battery.
<div class="toccolours mw-collapsible mw-collapsed">
<div style="font-weight:bold;line-height:1.0;">
QQ10: Run <code>sudo i2cdetect -y 1</code>, can't find I2C address 0x36?
</div>
<div class="mw-collapsible-content">
<div class="toccolours mw-collapsible mw-collapsed">
<div style="font-weight:bold;line-height:1.0;">
QQ11. How do you disable the X1202 auto-shutdown when you use it standalone (not installed on a RPi5)?
</div>
<div class="mw-collapsible-content">
<div class="toccolours mw-collapsible mw-collapsed">
<div style="font-weight:bold;line-height:1.0;">
QQ12. X1203 UPS voltage drops / low voltage warning appears?
</div>
<div class="mw-collapsible-content">
<div class="toccolours mw-collapsible mw-collapsed">
<div style="font-weight:bold;line-height:1.0;">
QQ13. Documentation about the I2C registers:
</div>
<div class="mw-collapsible-content">
[https://www.analog.com/media/en/technical-documentation/data-sheets/MAX17040-MAX17041.pdf MAX17040G+]
</div>
</div>
<div class="toccolours mw-collapsible mw-collapsed">
<div style="font-weight:bold;line-height:1.0;">
Q14. Why does the RPI 5 lose power within a few seconds after pressing the power button on the X120x UPS?
</div>
<div class="mw-collapsible-content">
A:
'''Please note: If the UPS does not detect the RPi5, it will automatically shut down within 3 seconds. So you need to install the RPi 5 on the UPS and make sure that the RPi5 has good contact with the UPS's pogo pins.'''
</div>
</div>
<div class="toccolours mw-collapsible mw-collapsed">
<div style="font-weight:bold;line-height:1.0;">
Q15. Which product should I choose if I can’t connect to a Raspberry Pi via pogo pins?
</div>
<div class="mw-collapsible-content">
A:
For the X12-UPS series, we recommend the '''[[X1206]]''' – models from X1200 to X1205 do not support this usage. The X120- UPS series auto-powers off when no Raspberry Pi 5 is detected, while the X1206 can be set to "Always Power On" mode and keeps working even if the Raspberry Pi is shut down. Please refer to <span style="color:red">'''Interface ⑩_ALON'''</span> in the picture.
[[File:X1206-IMG-7240-Interface-New.jpg|800px]]
You can also consider the '''[[X-UPS1]]'''. It features a GPIO Pin-Connected standalone design with high flexibility for installation and adaptation (refer to the picture).
[[File:X-UPS1-IMG-5409.jpg|800px]]
</div>