Q: Why does the UPS shield continue to output power when PI 5 is turned off via press the on-board button?
+
Q: Why is the RPi5 LED still on and red after the UPS is turned off?
 
</div>
 
</div>
 
<div class="mw-collapsible-content">
 
<div class="mw-collapsible-content">
 
A:
 
A:
The UPS shield provides enhanced power management features that intelligently monitor the power status of the Raspberry Pi 5 and automatically cut off power when the Pi is powered off. This helps optimize battery life by entering an ultra-low standby power consumption mode. It ensures efficient operation and maximizes the lifespan of the UPS battery.
+
Please set as follows:
  
'''To get the above features, check that the following settings are complete'''
+
Open the Teminal window based on '''Raspberry Pi OS''' and execute the following command:
 +
sudo rpi-eeprom-config -e
 +
Add <code>PSU_MAX_CURRENT=5000</code> at the end of the file that reads like this:
  
[[File:Pi5-ups-setting.png|800px]]
+
[[File:X1012-setting.png|700px]]
 +
 
 +
Press '''Ctrl-O''', then enter, to write the change to the file.
 +
 
 +
Press '''Ctrl-X''' to exit nano (the editor).
 +
 
 +
'''Reboot''' your Raspberry Pi 5 to make the change take effect.
 
</div>
 
</div>
 
</div>
 
</div>

Revision as of 16:13, 6 January 2025

Expand

Q: Why does the message "This power supply is not capable of supplying 5A" appear??

Expand

Q: How to disable auto power on feature on X1200?

Expand

Q: How to disable auto power on feature on X1201?

Expand

Q: How to disable auto power on feature on X1202?

Expand

Q: How to disable auto power on feature on X1203?

Expand

Q: Why is the RPi5 LED still on and red after the UPS is turned off?

Expand

Q: What battery is recommended for this ups shield

Expand

Q: Run sudo i2cdetect -y 1, can't find I2C address 0x36?

Expand

Q. How do you disable the X1202 auto-shutdown when you use it standalone (not installed on a RPi5)?

Expand

Q. X1203 UPS voltage drops / low voltage warning appears?